Secop 117U5012 125µF Compressor Start Capacitor – CAP313DF

£13.95 inc VAT
£11.63 ex VAT

Available on backorder. Stock is awaiting arrival. Dispatch will take place after stock has been received; the dispatch date will be confirmed.

Secop 117U5012 125µF Compressor Start Capacitor – CAP313DF

Replacement capacitor for equipment using the matching electrical specification. Check the original label before selecting your part.

  • Capacitance: 125µF
  • Duty: motor start capacitor

Fit check: Match capacitance, start/run duty, case size, mounting and terminals. Start and run capacitors are not interchangeable.

Ask Brave Coolers before ordering with a photo of the original label if you need help. Fitting and discharge must be carried out by a competent person.

🚚 UK Delivery Information
Delivery options and applicable charges are shown at checkout. For urgent spare parts orders, contact us before 2:00 PM (Mon–Fri) to confirm stock and dispatch. Large equipment, cold rooms and special courier items have separate delivery arrangements.
Spare parts delivery — VAT included
Orders up to £60: £4.90. Orders over £60 up to £100: £6.95. Orders over £100: FREE. Based on the spare-parts total after discounts, including VAT. UK mainland, parcels up to 15kg; restricted destinations and heavier parcels require a quote.

Available on back-order

Description

Choose a matching replacement capacitor for your equipment. Compare the original electrical rating and duty type; visual similarity alone is not sufficient.

Product identification

  • Capacitance: 125µF
  • Rated voltage: the stated voltage
  • Duty/type: motor start capacitor
  • Supply: one capacitor unless a pack quantity is explicitly stated

Check before ordering

Confirm the full µF value or range, AC voltage rating, start-versus-run duty, tolerance, terminal style, case diameter/height and mounting method against the original. A start capacitor must not be substituted for a continuous-duty run capacitor, or vice versa. Equipment and brand names in the title are compatibility search references only.

Electrical safety

Capacitors can retain a hazardous charge after equipment is isolated. Installation, discharge and testing should be carried out by a competent person using suitable procedures and test equipment. Replace any failed associated relay or wiring fault before returning the equipment to service.

Model Compatibility & OEM

Model compatibility and reference numbers

OEM / part referenceNot specified — please confirm before ordering.
Listed brandsNot specified — please confirm before ordering.
Listed modelsNot specified — please confirm before ordering.

Reference numbers and brand names assist identification; they do not by themselves confirm fit or genuine OEM manufacture. Check the full model and part number, dimensions and electrical specifications. If unsure, send us a photograph of the rating plate and original part before ordering.

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Secop 117U5012 125µF Compressor Start Capacitor – CAP313DF”

Your email address will not be published. Required fields are marked *