£1,049.13 ex VAT
£1,355.00 ex VAT
Eliwell EWRC500 NT Coldface Controller with Circuit Breaker — 230V
£195.95 inc VAT
£163.29 ex VAT
230V single-phase EWRC500NT Coldface panel, five relays, circuit breaker fitted, no real-time clock. 12A reference compressor relay rating. Probes selected separately. English setup PDF below.
Delivery options and applicable charges are shown at checkout. For urgent spare parts orders, contact us before 2:00 PM (Mon–Fri) to confirm stock and dispatch. Large equipment, cold rooms and special courier items have separate delivery arrangements.
Orders up to £60: £4.90. Orders over £60 up to £100: £6.95. Orders over £100: FREE. Based on the spare-parts total after discounts, including VAT. UK mainland, parcels up to 15kg; restricted destinations and heavier parcels require a quote.
Eliwell EWRC500 NT Coldface panel with circuit breaker
230V single-phase cold-room controller with five output relays for compressor, defrost, fans, light and alarm functions. Electric/hot gas defrost is configured to suit the installation. Range image is representative.
Technical specification
- Supply: 230V AC, single phase
- Compressor relay reference rating: 12A; check motor starting current and the manufacturer’s load category before direct switching
- Outputs: 5 relays
- Real-time clock / HACCP clock: not fitted on this variant
- Circuit breaker: fitted; verify its rating against the exact supplied reference
- NTC/PTC input selection according to model parameters
- Enclosure protection: IP65 when installed as instructed
Included
One EWRC500NT panel with circuit breaker. Probes are selected separately; not represented as included.
Accessories / select separately
Compatible room and evaporator probes, cable glands and wiring, external contactors and overload protection where loads exceed the permitted switching category, and application-specific solenoid/coil. RS485 supervision may require an optional interface; no networking accessory is represented as included.
Setup and manufacturer’s PDF
Eliwell EWRC 300/500/5000 NT — English user manual (PDF)
Match the complete panel reference and wiring diagram before connecting loads. Set the probe type, room setpoint and differential; configure defrost type, interval, maximum duration and termination probe; then check drip time, fan delay, door input and high/low temperature alarms. Validate all outputs and alarm operation during commissioning. Settings depend on the cold room and evaporator; follow the manual rather than copying universal values.
Delivery
Estimated delivery: 2 working days, subject to stock and postcode confirmation. Delivery charges shown at checkout.
| Brand | Eliwell |
|---|---|
| Model | EWRC500 NT |
| Supply | 230V single phase |
| Circuit breaker | Yes |
| Real-time clock | No |
| Outputs | 5 relays |
Model compatibility and reference numbers
| OEM / part reference | Not specified — please confirm before ordering. |
|---|---|
| Listed brands | Not specified — please confirm before ordering. |
| Listed models | Not specified — please confirm before ordering. |
Reference numbers and brand names assist identification; they do not by themselves confirm fit or genuine OEM manufacture. Check the full model and part number, dimensions and electrical specifications. If unsure, send us a photograph of the rating plate and original part before ordering.
Related products
Eliwell EWRC500NT Digital Cold Room Controller with 2 Probes
In stock
£162.46 ex VAT

Reviews